Lucent Technologies SLC ConnectReach User & Service Manual page 408

Access system
Table of Contents

Advertisement

Configure/Monitor and Upgrade Software for the SLC
ConnectReach System Using a Web Browser
Executing Commands from the Main Menu
Using a Web Browser to Upgrade
Software (Continued)
Displaying and
using the network-
upgrade screen
(continued)
8-20
Issue 4
June 2002
Step
Procedure
8
To start the download, click the Update button.
As the download occurs, progress messages similar to the following are
displayed at the bottom of the screen:
1 meg of RAM allocated for preparing flash
using version <24A1>
Opening FTP connection to
flash:/download/lucent.st_rom.24A1
Downloading 425632 bytes
Read 0 of 425632 bytes
...
Read 425632 of 425632 bytes
downloaded standalone boot from
/download/lucent.st_rom.24A1
Checksum ffff5b80 OK.
DONE
9
After the download completes, the SLC ConnectReach system saves the
new software in the system image partition of Flash memory and
performs a warm restart. During this process, messages similar to the
following are displayed at the bottom of the screen:
Saving image
using version <24A1>
using 1 meg buffer allocated at 0x81de724
writing standalone section (425644 bytes starting @
0x20000
Time spent: 27 seconds
Wrote standalone section OK
DONE
Rebooting ...
10
Wait approximately 60 seconds and then select the Back button on your
browser. The Network-upgrade screen appears. Select main menu,
enter your user name and password when prompted, and then select
version to verify the software.
Stop! End of Procedure.
363-208-050
(Continued on next page)