Mount the SLC
ConnectReach
Wall Mounting (Continued)
Wall mount using
hinged wall mount
assembly
System
Use the following procedure to mount one or multiple (up to four) SLC
ConnectReach systems on a wall using the hinged wall mount assembly.
Step
Procedure
1
Using the template provided with the mounting assembly, mark the
location of the mounting holes on the wall. The template contains two
different sets of mounting holes (refer to the following figure). The four
smaller holes (0.30 inches in diameter) in the assembly are used to
temporarily hang the assembly while installing the screws in the six larger
holes (0.40 inches in diameter).
NOTE:
The hinged wall mount assembly must be mounted so that the
hinge is on the left or right side. Failure to comply will void UL
certification of the assembly.
CAUTION:
The hinged wall mount assembly must be mounted to a minimum
¾-inch thick plywood that is securely fastened to the mounting wall.
363-208-050
(Continued on next page)
Issue 4
June 2002