Software Upgrade, Maintenance, and Trouble Clearing
Maintenance Procedures
Upgrading the SLC ConnectReach System
with New Software (Continued)
Software upgrade
from the network
(continued)
9-8
Issue 4
June 2002
NOTE:
Be sure to specify the correct version number. If more than one version is
present in the download directory, and you accidentally specify an older
version than the SLC ConnectReach system is already running, the
download will still take place, and the old software will overwrite the new
software.
After the download completes, the SLC ConnectReach system Utility saves the
software in the system image partition of Flash memory and performs a warm
restart. Refer to the section entitled "Rebooting the SLC ConnectReach system",
located later in this chapter, for a description of the difference between warm-start
and cold-start.
Normal Network Upgrade
The network upgrade server is by default Lucent's server; therefore, it is not
necessary to specify the server or the software release. However, the domain
name service (DNS) server must be configured and enabled for the
network-upgrade to function. Refer to Chapter 4, "Configuring the SLC
ConnectReach
System" for information on configuring the DNS server. For all
normal upgrades, proceed as follows:
Step
Procedure
1
At the Main Menu prompt, enter the network-upgrade command:
> network-upgrade
2
Set the version to the one you want to download (for example, Software
Release 3.0.2 would be entered as ver 302 )
(Network-upgrade)> ver XXXX
3
Set the user to anonymous:
( Network-upgrade )> user anonymous
4
Set the password to an email address (the Lucent support address is
used as an example here):
Enter password : support@lucent.com
363-208-050
®
(Continued on next page)