Lucent Technologies SLC ConnectReach User & Service Manual page 116

Access system
Table of Contents

Advertisement

®
Configuring the SLC
ConnectReach
Using the Configuration Commands
Configuring the Secondary/Fractional
T1/DSX-1 Interface (Continued)
Procedure
4-30
Issue 4
June 2002
System
Step
Procedure
2
At the Config:Secondary/Fractional T1 prompt, enter the appropriate
commands from the following table. The default setting for each
command appears in brackets.
To
Enable secondary/fractional
T1/DSX-1
Set the framing format
Set the line coding format
Set the build out in feet or
*
decibels
Comply with ones density
specification (applies only to
AMI line coding format)
Enables the alarm operation
Sets the delay between a
secondary/fractional T1/DSX-1
alarm and closing of the alarm
relay.
Set the secondary/fractional
T1/DSX-1 to accept a slave
from a stand alone
ConnectReach system (allows
for 25-48 ports for voice only). has-slave
Access online assistance
*
The line buildout command may be specified for connection to a CSU or to a DSX. For a
CSU, the value is specified in decibels (dB); for a DSX, the value is specified in feet.
Enter this
command...
...and one of these options
enable
On, [Off]
framing
[ESF], D4
linecode
[B8ZS], AMI
[0-133ft(DSX)/
0dB(CSU)],
133-266ft(DSX),
266-399ft(DSX),
399-533ft(DSX),
533-655ft(DSX),
–7.5dB(CSU), –
15dB(CSU),
buildout
–22.5dB(CSU)
pulse-
density-
enforce
On, [Off]
alarm-
operation
[off], on
alarm-delay 0..[15]..3600 sec
[off], on
Help
(Continued on next page)
363-208-050