Configuring the SLC
ConnectReach
Using the Configuration Commands
Configuring the SNMP Service
(Continued)
Procedure
(continued)
System
Step
Procedure
At the Config:SNMP prompt, enter the t1-traps command (T1/DSX-1
3
interface) .
(config:SNMP)> t1-traps
The prompt changes to the Config:SNMP:T1 prompt.
(config:SNMP:T1)>
The following table lists the T1traps. These traps set the T1 thresholds
encountered by a DS1 interface. If the threshold is reached within the
current 15-minute period, the associated trap will be sent. To disable a T1
trap, set it to 0.
T1 Traps
ESs-threshold
SESs-threshold
SEFs-threshold
UASs-threshold
CSSs-threshold
PCVs-threshold
LESs-threshold
BESs-threshold
DMs-threshold
LCVs-threshold
4
When you have made the necessary configuration changes, you can
return to the Config menu by typing exit or an exclamation point (!)
(quoted as "\ |" through the SLC-2000 Access System CIT)
NOTE: If you change any of these commands, you must save the
configuration and reboot the SLC ConnectReach system using the
warm-start command for the new settings to take effect.
NOTE: If the Network T1/DSX-1 connection is a frame relay network
and you have established a secondary PVC to the carrier's
management network, the SNMP-host command should be set to an
address on that network.
Stop! End of Procedure.
Description
The number of Errored Seconds (ESs)
The number of Severely Errored Seconds (SESs)
The number of Severely Errored Framing Seconds (SEFs)
The number of Unavailable Seconds (UASs)
The number of Controlled Slip Seconds (CSSs)
The number of Path Coding Violations (PCVs)
The number of Line Errored Seconds (LESs)
The number of Bursty Errored Seconds (BESs)
The number of Degraded Minutes (DMs)
The number of Line Code Violations (LCVs)
.
Issue 4
June 2002
4-111
363-208-050