Chapter 4 Tutorials
4 Configure the IMA group.
Click IMA > Group.
Select Slot 2 and Port 3, then click Load.
Configure the settings and note the following:
• Do not select Enable since some settings (Group Symmetry and Frame Size) in the
screen can be changed only when the group is disabled.
• The Group Symmetry and Version settings should be the same on the both peers.
• The Clock Mode setting can be different between the peers, however, you will see an
alarm when they are different.
• Click Apply.
Figure 33 Configure the IMA Group Example
5 Associate the E1 port with the IMA group.
Click the none link in the Link field of the IMA > Group screen. The Select member
links window pops up.
Select port 3 and click Apply to go back to the IMA Group Setup screen.
Figure 34 Associate the E1 Port with the IMA Group Example
6 Enable the IMA group.
Select Enable and click Apply.