Chapter 14 Statistics Screens
Table 224 IMA Statistics: IMA Line Card: Group Detail (continued)
LABEL
Unavailable
Seconds (secs)
Ne Num Failures
Fe Num Failures
Test Link id
Test Patterns
Test Processing
Status
Valid 15 minutes
Interval
Invalid 15 minutes
Interval
TimeElapsed(secs
)
Min Num Links
TRL Link Id
Ima Id
Frame Length(cell) This field displays the number of ATM cells the IMA converts into a frame.
Available Cell Rate This field displays the current transmission (Tx) or receiving (Rx) cell rate in bps,
Num Cfg Links
Num Act Links
Oam Label Value

14.23.3 Link Details

To display the details of an E1 link on the selected IMA group, click the slot number in the
Statistics > IMA screen, the index number of the IMA group (see
and then the number of a link.
456
DESCRIPTION
This field displays the number of the unavailable seconds for this IMA group.
This field displays the number of times a failure on this IMA group has been
reported by the IMA line card since it was booted up.
This field displays the number of times a failure on this IMA group has been
reported by the remote IMA device since it was booted up.
This field displays the index number of a link that is currently used in the Test
Pattern Procedure. 0 displays if no link has yet been added to this IMA group.
This field displays the Test Pattern used for sending across a link for verifying the
connectivity of the link between the two IMA devices.
This field displays whether the Test Pattern Procedure is enabled (operating) or
disabled (disabled) in this IMA group as well as any link in this group that failed
the test (linkfail).
This field displays the number of previous 15 minute intervals for which valid data
was collected.
This field displays the number of previous 15 minute intervals for which no valid
data was collected.
This field displays the number of seconds that have elapsed since the beginning
of the current measurement period.
This field displays the minimum number of transmission (Tx) or receiving (Rx)
links required to be active for keeping the IMA group in the operational state.
This field displays the index number of the transmission (Tx) or receiving (Rx) link
from which the IMA line card uses the clock time for fixing the time of data cells.
This field displays the indentifier of an IMA line card that is currently used by the
IMA line card (Tx) or the remote IMA device (Rx).
considering all links in the IMA group are in active.
This field displays the number of links in this group that are configured as
transmission links (Tx) or receiving links (Rx).
This field displays the number of links in this group that are configured as
transmission links (Tx) or receiving links (Rx) and are currently active.
This field displays the IMA OAM label value transmitted by the IMA line card (Tx)
or the remote IMA device (Rx). 0 displays if the IMA line card did not receive any
OAM labels from the remote IMA device until now.
Figure 311 on page
MSC1000G/1024G/1224G Series User's Guide
452)