Chapter 13 Profile Screens
The following table describes the fields in this screen.
Table 174 Alarm E1 Profile
LABEL
The top part of the screen is for profile configuration.
Name
Threshold
Qes [0~900]
Qses [0~900]
Quas [0~900]
Dayes [0~86400]
Dayses [0~86400] This field sets the limit for the number of Severely Errored Seconds that are
Dayuas [0~86400] This field sets the limit for the number of UnAvailable Seconds that are permitted
Apply
New
Cancel
The bottom part of the screen lists the configured profiles.
Index
Name
Modify
Delete
396
DESCRIPTION
Type a name to identify the alarm profile (you cannot change the name of the
DEFVAL profile). You can use up to 31 English keyboard characters; spaces are
not allowed.
Specify limits for the individual performance counters. The system sends an alarm
trap and generates a syslog entry when one of these thresholds is exceeded. A
value of 0 disables the alarm threshold.
This field sets the limit for the number of Errored Seconds that are permitted to
occur within 15 minutes.
This field sets the limit for the number of Severely Errored Seconds that are
permitted to occur within 15 minutes.
This field sets the limit for the number of UnAvailable Seconds that are permitted
to occur within 15 minutes.
This field sets the limit for the number of Errored Seconds that are permitted to
occur within one day.
permitted to occur within one day.
to occur within one day.
Click Apply to save the changes in this screen to the system's volatile memory.
The system loses these changes if it is turned off or loses power, so use the
Config Save on the navigation panel and then the Save button to save your
changes to the non-volatile memory when you are done configuring.
While you are modifying a profile, you can click New to start configuring a fresh
profile without saving your changes.
Click Cancel to start configuring the screen again.
This is the index number of the alarm profile.
This is the name of the alarm profile.
Select a profile's Select radio button and click Modify to edit the profile.
Select a profile's Select radio button and click Delete to remove the profile.