Chapter 22 alarm Commands
The following example removes the historic minor level alarms for all alarm categories, and
all conditions.
ras> alarm history clear minor

22.3.5 alarm history show Command

Syntax:
alarm history show [<severity>|all] [<alarm>|all] [<condition>|all]
[<sdate>|all] [<edate>|all] [for|rev] [detail]
This command displays historic alarms by severity, alarm category or alarm condition.
The following example displays the historic major level alarms for all alarm categories, and all
conditions.
ras> alarm history show major
no alarm
------ ------
1 eqpt
2 eqpt
3 eqpt
4 eqpt

22.3.6 alarm port set Command

Syntax:
alarm port set all|mgmt|<giga-port>|<slot-port> <severity>
where
<fac>
<target>
This command sets the alarm severity threshold for recording alarms on an individual port(s).
The system reports an alarm on a port if the alarm has a severity equal to or higher than the
port's threshold.
The following example has the systems only record critical alarms on DSL port 7 on the line
card in slot 4.
ras> alarm port set 4-7 critical

22.3.7 alarm port show Command

Syntax:
alarm port show <slot>
616
condition
------------------------ -------- -------------- -------
+LT_INACTIVE
+LT_INACTIVE
-LT_INACTIVE
-LT_INACTIVE
=
The log facility (
local1
messages to different files in the syslog server. See your syslog program's
documentation for details.
snmp|syslog|all|none
=
is to send (SNMP, syslog or all).
category.
severity timestamp
major
09/09 09:38:54 slot 4
major
09/09 09:38:54 slot 9
major
09/09 09:39:25 slot 4
major
09/09 09:39:28 slot 9
~
local7
) that has the device log the syslog
The type of alarm messages that the device
none
disables alarm reports on this alarm