1 Enable the E1 port.
Click Port > E1.
Select Slot 2 and Port 3, then click Load.
Select Enable and then click Apply.
Figure 31 Enable the E1 Port Example
Check the port 3 LED. The LED should be orange. An orange LED indicates an alarm
on the link.
2 Connect the link 3 wires.
Find link 3's wires. You may need to refer to the Telco-50 connector pin assignments in
your IMA line card User's Guide.
Connect the Tx wire to the Rx wire from your service provider and similar for the Rx
wire connection.
Click Alarm, if you see Loss-of-Signal (LOS) and out-of-CRC alarms on the port, make
sure you are using the correct wires.
3 Configure the E1 port settings.
Click Port > E1.
Select Slot 2 and Port 3, then click Load.
Configure the settings and then click Apply.
Figure 32 Configure the E1 Port Example
MSC1000G/1024G/1224G Series User's Guide
Chapter 4 Tutorials
85