Diagnostic Loopback Ima Commands - ZyXEL Communications MSC1024G Series User Manual

Managment switch card
Hide thumbs Also See for MSC1024G Series:
Table of Contents

Advertisement

The following example stops the E1 line loopback test on port 1 of slot 2 and then displays the
loopback testing mode.
ras> diagnostic loopback e1 set 2-1 0
ras> diagnostic loopback e1 show 2-1
slot-port
--------- --------------
2- 1

26.9 diagnostic loopback ima Commands

Use these commands to perform an IMA loopback test on an IMA group.
26.9.1 diagnostic loopback ima Commands
Syntax:
diagnostic loopback ima enable <slot-gid> <link-id> <pattern>
This command performs an IMA loopback test on the specified IMA group and link of the
specified slot. The link must be a member of the specified IMA group.
Syntax:
diagnostic loopback ima show <slot-gid>
This command displays the IMA loopback testing setting of the specified IMA group.
Syntax:
diagnostic loopback ima disable <slot-gid>
This command stops the previous IMA loopback test for the specified IMA group.
The following example performs an IMA loopback test using a testing pattern ff on IMA
group 3 and link 1 of slot 2. Then it also displays the settings.
ras> diagnostic loopback ima enable 2-1 3 ff
ras> dia loopback ima show 2-1
slot-group
----------- ------- ------------
2 - 1
received pattern
1
---- ---- ---- ---- ---- ---- ---- ----
0
--
MSC1000G/1024G/1224G Series User's Guide
E1 LPBK mode
None LPBK
status
test pattern
enable
ff
2
3
4
5
--
00
00
--
--
Chapter 26 diagnostic Commands
6
7
8
--
--
643

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msc1224g seriesMsc1000g series

Table of Contents