The following table describes the labels in this screen.
Table 299 The VoIP > Key Pattern Screen
LABEL
Name
Service Type
callreturn
calltransfer
callwaitdisconn
callwaitoff
callwaiton
callwaitonhold
callwaitreject
clir
dndoff
dndon
callin
Apply
New
Cancel
Index
Name
Select
Modify
Delete
MSC1000G/1024G/1224G Series User's Guide
DESCRIPTION
Enter a name for this key pattern profile (up to 31 ASCII characters; spaces
are not allowed).
These fields control the telephone keys a user presses to access a
particular service. Characters are limited to the numerals 0~9, the pound
(#) and asterisk (*).
Enter the sequence of keys the user presses to dial the last number to call
the user (1~7 characters).
Enter the sequence of keys the user presses to enable a call transfer (1~7
characters).
Enter the key the user presses to disconnect a current call and accept a
waiting call (one character only).
Enter the sequence of keys the user presses to turn call waiting off (1~7
characters).
Enter the sequence of keys the user presses to enable call waiting (1~7
characters).
Enter the key the user presses to place a current call on hold and accept a
waiting call (one character only).
Enter the key the user presses to reject a waiting call (one character only).
Enter the sequence of keys the user presses to restrict his/her phone
number by not sending caller ID information (1~7 characters).
Enter the sequence of keys the user presses to turn off Do Not Disturb
(1~7 characters).
Enter the sequence of keys the user presses to turn on Do Not Disturb
(1~7 characters).
Enter the sequence of keys the user presses to turn on the Call In feature.
When the Call In feature is active, the system limits call ringing time to ten
seconds.
Click Apply to save the changes in this screen to the system's volatile
memory. The system loses these changes if it is turned off or loses power,
so use the Config Save on the navigation panel and then the Save button
to save your changes to the non-volatile memory when you are done
configuring.
While you are modifying a profile, you can click New to start configuring a
fresh profile without saving your changes.
Click Cancel to start configuring the screen again.
This is an incremental number indicating the order in which the profiles
were created.
This is the name of the profile.
Select the profile you wish to modify or delete.
Select a profile and click this to edit its configuration.
Select a profile and click this to delete the profile. Once deleted,
information cannot be retrieved.
Chapter 18 VoIP