ZyXEL Communications MSC1024G Series User Manual page 519

Managment switch card
Hide thumbs Also See for MSC1024G Series:
Table of Contents

Advertisement

Table 272 Sys > Monitor (continued)
LABEL
high_lmt
low_limit
Temperature
Index
temperature
current
high_lmt
low_limit
CPU
Index
cpu
current
high_lmt
Fan
Index
fan
MSC1000G/1024G/1224G Series User's Guide
DESCRIPTION
Use these fields to set the maximum voltage threshold for each sensor.
The maximum voltage for each voltage sensor must be within the following
ranges. Measured in millivolts (mV).
MSC: 1 = 2575~2750, 2 = 1287~1375, 3 = 3399~3630, 4 = 1339~1430, 5 =
15450~16500
ADSL line card: 1 = 1236~1320, 2 = 1854~1980, 3 = 3399~3630, 4 =
21115~22550
SHDSL line card 1 = 1854~1980, 2 = 3399~3630, 3 = 15450~16500
VDSL line card 1 = 3399~3630, 2 = 12360~13200, 3 = 1236~1320, 4 =
1236~1320, 5 = 1854~1980
VoIP line card 1 = 1339~1430, 2 = 2575~2750, 3 = 3399~3630, 4 = 3399~3630,
5 = 5150~5500
Ethernet line card 1 = 2575~2750, 2 = 1287~1375, 3 = 3399~3630, 4 =
5150~5500
Use these fields to set the minimum voltage threshold for each sensor.
The minimum voltage for each voltage sensor must be within the following
ranges. Measured in millivolts (mV).
MSC:1= 2250~2425, 2 = 1125~1212, 3 = 2970~3201, 4 = 1170~1261, 5 =
13500~14550.
ADSL line card: 1= 1080~1164, 2 = 1620~1746, 3 = 2970~3201, 4 =
18450~19885
SHDSL line card: 1 = 1620~1746, 2 = 2970~3201, 3 = 13500~14550
VDSL line card 1 = 2970~3201, 2 = 10800~11640, 3 = 1080~1164, 4 =
1080~1164, 5 = 1620~1746
VoIP line card 1 = 1170~1261, 2 = 2750~2425 3 = 2970~3201, 4 = 2970~3201,
5 = 4500~4850
Ethernet line card 1 = 2250~2425, 2 = 1080~1164, 3 = 970~3201, 4 =
4500~4850
Each temperature sensor can detect and report the temperature.
This field displays the number of the temperature sensor in the list.
This field displays the name of the temperature sensor.
This field displays the current temperature at this sensor (in degrees Celsius).
Use these fields to set the maximum temperature threshold for each sensor.
The maximum temperature for each temperature sensor must be within 50~100
(degrees Celsius).
Use these fields to set the minimum temperature threshold for each sensor.
The minimum temperature for each temperature sensor must be within -50~10
((degrees Celsius).
The system can detect and report the utilization of each card's CPU.
This field displays the number of the CPU in the list.
This field displays the name of the CPU.
This field displays the current percentage of CPU utilization.
Use this field to set the maximum utilization threshold for the CPU.
These fields display when you select the MSC. A properly functioning fan is an
essential component (along with a sufficiently ventilated, cool operating
environment) in order for the device to stay within the temperature threshold.
Each fan has a sensor that can detect and report the fan's RPM (Rotations Per
Minute).
This field displays the number of the fan in the list.
This field displays the name of the fan.
Chapter 16 Sys Screens
519

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msc1224g seriesMsc1000g series

Table of Contents