Chapter 32 profile Commands
where
<profile>
This command displays which PVCs or PPVCs are set to use the specified ATM profile.
The following example displays which PVCs or PPVCs use the silver profile.
ras> profile atm map silver
32.11 Profile Server
The profile server feature manages profiles on multiple IES's. You can configure profiles on
one IES that you set to server mode. When you want to configure another IES, you can set it to
client mode to get the profile settings from (synchronize with) the IES in server mode. If you
change the profile settings on the IES in server mode, you can have it synchronize the profile
settings on the clients to match.
32.12 profile ipqos Commands
Use these commands to configure the profile server feature settings.
32.12.1 profile ipqos set Command
Syntax:
profile ipqos set <profile> <number_of_queues>
This command adds an IPQoS profile named EXAMPLE with 8 queues.
ras> profile ipqos set EXAMPLE 8
32.12.2 profile ipqos show Command
Syntax:
profile ipqos show [profile]
786
=
The name of a profile.
MSC1000G/1024G/1224G Series User's Guide