ZyXEL Communications MSC1024G Series User Manual page 361

Managment switch card
Hide thumbs Also See for MSC1024G Series:
Table of Contents

Advertisement

Figure 227 Alarm SHDSL Profile
The following table describes the fields in this screen.
Table 159 Alarm SHDSL Profile
LABEL
The top part of the screen is for profile configuration.
Name
Threshold
LoopAttenuation
[0~127] (dB)
SNRMargin
[0~15] (dB)
ES [0~900] (sec)
SES [0~900] (sec) The number of Severely Errored Seconds (0~900) that are permitted to occur
CRCanomalies
[0~2147483647]
LOWS [0~900]
(sec)
UAS [0~900]
Apply
MSC1000G/1024G/1224G Series User's Guide
DESCRIPTION
Type a name to identify the alarm profile (you cannot change the name of the
DEFVAL profile). You can use up to 31 English keyboard characters; spaces are
not allowed.
Specify limits for the individual performance counters. The system sends an alarm
trap and generates a syslog entry when one of these thresholds is exceeded. A
value of 0 disables the alarm threshold.
The permitted attenuation (reduction of signal amplitude) of a port's connection.
The permitted signal to noise ratio margin.
The number of Errored Seconds (0~900) that are permitted to occur within 15
minutes.
within 15 minutes.
The number of Cyclic Redundancy Checking anomalies that are permitted to
occur within 15 minutes.
The number of Loss Of Sync Word Seconds (0~900) that are permitted to occur
within 15 minutes.
The number of UnAvailable Seconds (0~900) that are permitted to occur within 15
minutes.
Click Apply to save the changes in this screen to the system's volatile memory.
The system loses these changes if it is turned off or loses power, so use the
Config Save on the navigation panel and then the Save button to save your
changes to the non-volatile memory when you are done configuring.
Chapter 13 Profile Screens