Port Shdsl Pbo Command - ZyXEL Communications MSC1024G Series User Manual

Managment switch card
Hide thumbs Also See for MSC1024G Series:
Table of Contents

Advertisement

where
span|stuc|stur|*
<alarmprofile>
This command sets the specified SHDSL port(s) or end point(s) to use an alarm profile.
The following example sets SHDSL port 8 on the line card in slot 6 to use the SESalarm alarm
profile at both the STU-C and the STU-R.
ras> port shdsl alarmprof 6-8 * SESalarm

31.28.2 port shdsl pbo Command

Syntax:
port shdsl pbo <slot-port> normal_epl|forced_epl|forced_no_epl <value>
where
normal_epl|forced
_epl|forced_no_ep
l
<value>
This command sets the power backoff feature setting on the specified SHDSL port(s). Power
backoff calculates how much power is needed for the connection. This allows the STU-C and
STU-R to use only enough power for the port's maximum transmission rate (configured in the
SHDSL profile). You can normally just leave the default setting (
need to use this command if the STU-R does not support EPL or you need to configure the
port to use a specific power backoff setting.
MSC1000G/1024G/1224G Series User's Guide
=
span
: Sets the alarm profile for the whole span. This is the entire
connection including any SHDSL regenerators that might be located
between the STU-C (SHDSL Termination Unit - Central) and STU-R
(SHDSL Termination Unit - Remote) end points. An SHDSL
regenerator amplifies the SHDSL signal in order to increase the
connection distance.
stuc
: Sets the alarm profile at STU-C (SHDSL Termination Unit -
Central) end point
: Sets the alarm profile at STU-R (SHDSL Termination Unit -
stur
Remote) end point
*
: Sets alarm profile at both STU-C and STU-R
The name of an SHDSL alarm profile.
=
=
normal_epl
: Power backoff with EPL (Estimated Power Loss).
Each end calculates an EPL and uses it in determining a power
backoff value for the other end to use.
Forced power backoff with EPL. The STU-C
forced_epl:
calculates an EPL and uses it in determining the power backoff
values for both ends. This can be used when the STU-R device
does not support EPL.
forced_no_epl
: Forced power backoff without EPL. The STU-
C uses the value you specify in determining the power backoff
values for both ends. This can be used when you have prior
knowledge about the physical line (loop).
=
This sets the 0~31 in dB.
When using
nornal_epl
maximum power backoff value.
When using
forced_no_epl
Chapter 31 port Commands
or
forced_epl
, this sets the
, this sets the power backoff value.
), you only
normal_epl
739