Figure 357 Access Control: SNMP
The following table describes the labels in this screen.
Table 265 Access Control: SNMP
LABEL
Get Community
Set Community
Trap Community
Version
Trap Destination
Version
IP
Port
Username
MSC1000G/1024G/1224G Series User's Guide
DESCRIPTION
Enter the get community, which is the password for the incoming Get- and
GetNext- requests from the management station. You can use up to 31 English
keyboard characters; spaces are not allowed.
Enter the set community, which is the password for incoming Set- requests from
the management station. You can use up to 31 English keyboard characters;
spaces are not allowed.
Enter the trap community, which is the password sent with each trap to the SNMP
manager. You can use up to 31 English keyboard characters; spaces are not
allowed.
Specify the SNMP version and access mode.
Select v2c to allow SNMPv2 read/write access.
Select v3 to allow SNMPv3 read/write access with additional user authentication
and data encryption options.
Select v3v2c to allow SNMPv3 read/write and SNMPv2 read-only access.
Enter the IP address of a station to send your SNMP traps to.
Specify the format of the SNMP trap PDU (Protocol Data Unit) to be sent. The
default is v2c.
Enter the IP address (in dotted decimal notation) of the trap server.
Enter the port number upon which the station listens for SNMP traps.
This field is applicable when you select v3 in the Version field.
Enter the username to be included in the trap PDUs.