Figure 83 Alarm Severity Assignment: DSL
The following table describes the labels in this screen.
Table 46 Alarm Severity Assignment: DSL
LABEL
Condition
Facility
SNMP
Syslog
Severity
Clearable
Select All
Apply
Cancel
MSC1000G/1024G/1224G Series User's Guide
DESCRIPTION
This identifies an individual alarm. See
information.
Select the log facility (local1~local7) to have the device log the syslog messages to
a specific file in the syslog server. See your syslog program's documentation for
details.
Select the check box to have the switch send SNMP traps of the specified alarm
condition.
Select the check box to have the switch send syslog messages of the specified
alarm condition.
Select the severity level from minor, major and critical for the specified alarm
condition. You cannot change the severity level of the info severity level alarms.
Select the check box to allow an administrator to manually remove records of the
specified alarm.
Select an option from the Select All drop-down list box to automatically select that
option for all entries. Alternatively, you may configure individual entries.
Select a Select All check box to automatically select that option for all entries. Clear
it to clear that option for all entries. Alternatively, you may select or clear the check
boxes for individual entries.
Click Apply to save the changes in this screen to the system's volatile memory. The
system loses these changes if it is turned off or loses power, so use the Config
Save on the navigation panel and then the Save button to save your changes to the
non-volatile memory when you are done configuring.
Click Cancel to begin configuring the screen again.
Chapter 6 Alarm Screens
Section 6.5 on page 150
for more
149