ZyXEL Communications MSC1024G Series User Manual page 828

Managment switch card
Hide thumbs Also See for MSC1024G Series:
Table of Contents

Advertisement

Chapter 33 show Commands
The following table describes labels in this example.
Table 330 show adsl tssi Command Display
LABEL
near end/far
end
tone
33.3.1.4 show adsl lineqln Command
Syntax:
show adsl lineqln <slot-port>
This command displays the Quiet Line Noise level on a line. This is the rms (root mean
square) level of the noise present on the line for a DMT tone when no ADSL or DSL signals
are present. It is measured in dBm/Hz. The QLN can be used in analyzing crosstalk.
The following example shows the Quiet Noise Level on port 1 of the line ADSL line card in
slot 3.
ras> show adsl lineqln 3-1
port 3-1:
near end: (dB/Hz)
tone
0 :
10 :
20 :
30 :
40 :
50 :
60 :
The following table describes labels in this example.
Table 331 show adsl lineqln Command Display
LABEL
near end/far
end
tone
33.3.1.5 show adsl linetssi Command
Syntax:
show adsl linetssi <slot-port>
828
DESCRIPTION
This shows the location of the line test. "near end" refers to upstream traffic, or
traffic from the CPE device. "far end" refers to downstream traffic, or traffic from
the CO device.
This shows the frequency in increments of 4.3125 KHz. Single digit units on the
top row are added to the units in tens on the left hand column to find the
corresponding value in the table. For example, to find the Hlog value for tone band
43, locate 40 in the left hand column and 3 in the top row. The intersection of the
column 3 and row 40 gives a Hlog value of 5.
1
2
3
------ ------ ------ ------ ------ ------ ------ ------ ------ ------
NA
-86.5
-86.5
-67.0
-76.0
-81.5
-83.5
-75.5
-82.5
-97.5
-95.5
-97.5
-106.5 -107.0 -108.0 -109.0 -109.5 -110.0 -110.5 -111.5 -111.5 -112.0
-112.0 -113.5 -113.0 -114.0 -115.0 -115.5 -114.5 -114.5 -115.5 -117.0
-116.0 -116.5 -116.5 -116.0
DESCRIPTION
This shows the location of the line test. "near end" refers to upstream traffic, or
traffic from the CPE device. "far end" refers to downstream traffic, or traffic from
the CO device.
This shows the frequency in increments of 4.3125 KHz. Single digit units on the
top row are added to the units in tens on the left hand column to find the
corresponding value in the table. For example, to find the QLN value for tone band
43, locate 40 in the left hand column and 3 in the top row. The intersection of the
column 3 and row 40 gives a QLN value of 5.
4
5
6
-85.5
-85.0
-83.5
-76.5
-86.0
-75.5
-77.0
-70.0
-40.5
-99.5 -100.5 -101.5 -102.5 -104.0 -105.0 -105.5
MSC1000G/1024G/1224G Series User's Guide
7
8
9
-82.0
-78.5
-69.0
-68.0
-37.5
-67.5
-72.5
-82.5
-90.0
10
-37.0
-75.0
-87.5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msc1224g seriesMsc1000g series

Table of Contents