Alarm Xedit Command - ZyXEL Communications MSC1024G Series User Manual

Managment switch card
Hide thumbs Also See for MSC1024G Series:
Table of Contents

Advertisement

The following example displays the supported alarms for all alarm levels, all alarm categories,
all facilities, all types of alarm messages and all conditions.
ras> alarm tablelist
no alarm
clearable
--- ------ -------------------------
1
dsl
2
dsl
3
dsl
4
dsl
-------------------------- [snip] --------------------------
17
dsl
18
dsl
19
dsl
Press any key to continue, 'e' to exit, 'n' for nopause

22.3.10 alarm xedit Command

Syntax:
alarm xedit <alarm> <cond> <severity> <fac> <target>[,<target>] <clearable>
where
<cond>
<fac>
<target>
<clearable>
This command sets the severity level of an alarm(s) and where the system is to send the
alarm(s). You can also set whether or not the alarm can be manually cleared from the system.
Use the
alarm tablelist
The following example creates an alarm report entry that sets all system alarms to the major
severity level and sends them to a syslog server at the local 3 log facility. It also sets the system
alarms to be manually clearable.
ras> alarm xedit sys all major local3 syslog clearable
MSC1000G/1024G/1224G Series User's Guide
(code)condition
( 5002)LINE_UP
( 5003)LINE_DOWN
( 5006)LINE_LDM_START
( 5007)LINE_LDM_END
( 5024)SHDSL_TCA_SNRM
( 5025)SHDSL_TCA_ES
( 5026)SHDSL_TCA_SES
=
<condition>|<code>|all: The condition is the text description for the
condition under which the alarm applies. Use the
command to find alarm conditions.
The condition code is the number of a specific alarm message. Use the
alarm tablelist
The log facility (
=
messages to different files in the syslog server. See your syslog program's
documentation for details.
=
snmp|syslog|all|none:
device is to send (SNMP, syslog or all).
this alarm category.
=
clearable|unclearable:
manually cleared from the system.
command to display alarm setting details.
facility snmp syslog severity
--------- ---- ------ -------- -------
local1
V
local1
V
local1
V
local1
V
local1
V
local1
V
local1
V
command to find alarm condition codes.
) that has the device log the syslog
local1~local7
The type of alarm messages that the
none
This sets whether or not the alarm can be
Chapter 22 alarm Commands
V
info
-
V
minor
V
V
info
-
V
info
-
V
info
V
V
info
V
V
info
V
alarm tablelist
disables alarm reports on
619

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msc1224g seriesMsc1000g series

Table of Contents