Chapter 34 switch Commands
Switches join VLANs by making a declaration. Declarations are withdrawn by issuing a Leave
message. GARP timers set declaration timeout values.
The following example sets the Leave Timer to 800 milliseconds.
ras> switch garptimer leave 800
34.7.4 switch garptimer leaveall Command
Syntax:
switch garptimer leaveall <leaveall msec>
where
<leaveall msec>
This command sets the system's leave all period timer for GVRP in milliseconds.
Switches join VLANs by making a declaration. A declaration is made by issuing a Join
message using GARP. A Leave All message terminates all registrations. GARP timers set
declaration timeout values.
The following example sets the Leave All Timer to 11000 milliseconds.
ras> switch garptimer leaveall 11000
34.7.5 switch garptimer set Command
Syntax:
switch garptimer set <join-msec> <leave-msec> <leaveall-msec>
where
<join msec>
<leave msec>
<leaveall msec>
This command sets the system's Join, Leave and Leave All timers.
886
=
This sets the duration of the Leave All Period timer for GVRP in
milliseconds. Each port has a single Leave All Period timer. Leave All
Timer must be larger than Leave Timer. The allowed Leave Time range
is between 201 and 65535 milliseconds; the default is 10000
milliseconds.
This sets the duration of the Join Period timer for GVRP in
=
milliseconds. Each port has a Join Period timer. The allowed Join Time
range is between 100 and 32767 milliseconds; the default is 200
milliseconds.
This sets the duration of the Leave Period timer for GVRP in
=
milliseconds. Each port has a single Leave Period timer. Leave Time
must be two times larger than Join Timer; the default is 600
milliseconds. The allowed Leave Time range is between 201 and
65534 milliseconds; the default is 600 milliseconds.
=
This sets the duration of the Leave All Period timer for GVRP in
milliseconds. Each port has a single Leave All Period timer. Leave All
Timer must be larger than Leave Timer. The allowed Leave Time range
is between 201 and 65535 milliseconds; the default is 10000
milliseconds.