26.6.1 diagnostic oam test Command

Syntax:
diagnostic oam test <slot-port> <pkt-number> <pktsize>
where
pkt-
number
pktsize
This command sends OAM loopback test Ethernet frames to a remote Ethernet device.
The following example sends 4, 64-byte OAM loopback test Ethernet frames to the remote
Ethernet device connected to port 13 of slot 7.
ras> diagnostic oam test 7-13 4 64

26.6.2 diagnostic oam show Command

Syntax:
diagnostic oam show <slot-port>
This command displays the results of the last Ethernet OAM loopback test that was run on the
specified Ethernet line card port.
The following example shows the result of the last test conducted on the line connected to port
13 of slot 7.
ras> diagnostic oam show 7-13
4 of 4 test ok, time =1(ms), 4000.0 (pkt/sec)
Test status: OK

26.7 diagnostic selt Commands

Use these commands to perform Single End Loop Tests on subscriber ports.

26.7.1 diagnostic selt show Command

Syntax:
diagnostic selt show <slot>|<slot-port>
This command displays the Single End Loop Test (SELT) result after you have performed a
SELT test on the specified port on the line card. The report tells you what gauge of telephone
wire is connected to the port and the approximate length of the line measured both in meters
(m) and thousands of feet (Kft).
MSC1000G/1024G/1224G Series User's Guide
Specify how many OAM loopback test Ethernet frames to send.
=
=
Specify the size of the OAM loopback test Ethernet frames (in bytes).
Chapter 26 diagnostic Commands
641