This table describes labels in the example.
Table 340 show monitor Command Information
LABEL
voltage
current
nominal
high_lmt
low_lmt
temperature
current
high_lmt
low_lmt
33.3.22 show mstp Command
Syntax:
show mstp <mstid> [<end_mstid>]
where
<mstid>
<end_mstid>
This command displays information (such as bridge ID, topology change counter, etc.) of the
specified MST region(s).
MSC1000G/1024G/1224G Series User's Guide
DESCRIPTION
The power supply for each voltage has a sensor that can detect and report the
voltage.
This is the present voltage reading.
This field displays the average voltage measured at this sensor.
This field displays the high voltage threshold for this sensor.
This field displays the low voltage threshold for this sensor.
This example displays the temperature measurements in degrees Celsius.
Each temperature sensor can detect and report the temperature. Temperature
sensor 1 is near the ADSL line driver. Temperature sensor 2 is near the main
chipset. Temperature sensor 3 is near the central processing unit.
This shows the current temperature at this sensor.
This field displays the high temperature threshold for this sensor.
This field displays the low temperature threshold for this sensor.
The first MST region ID.
=
=
The last MST region ID.
Chapter 33 show Commands
849