status isdn-testcall

status isdn-testcall
status isdn-testcall group# / member# [print]
Examples
status isdn-testcall 78/1 print
This command displays the progress of an outgoing ISDN-PRI test call on the
trunk specified. The tested ISDN-PRI B channel's port number, bit error rate,
number of bits transmitted, block error rate, number of blocks transmitted, start
time, duration specified, duration of test call, and reason of termination are
displayed on the status form.
If the bit error rate or block error rate is greater than zero, the ISDN-PRI trunk
"may" be in a troubled state. Based on the statistical information displayed on the
terminal, it can be decided to take the ISDN trunk out of service. This is subjective
data because the ISDN trunk may be used for data or voice. If the trunk is used
for data and the rates are high, the trunk should be taken out of service. If the
trunk is used for voice, the trunk may not have to be taken out of service. High
rates may also be due to some type of power hit on the line.
Output
This field specifies the physical address of the ISDN-PRI B channel.
Port
The measured bit error count according to the comparison of the sent and
Bit Error Rate
received bit pattern. The number is displayed in scientific notation.
The number of bits generated. The number is displayed in scientific notation.
Number of Bits
The measured block error count according to the comparison of the sent and
Block error
received bit pattern. The number is displayed in scientific notation.
Rate
The number of blocks generated. The number is displayed in scientific
Number of
notation.
Blocks
The time the test call started (dd/hh:mm).
Start Time
555-233-143