status health
Maj, Min, Wrn
PNC
Time of Day
555-233-143
Number of major, minor or warning alarms associated with the cabinet
An asterisk indicates that the number exceeds 999
Current Port Network Connectivity (PNC) status for each of the port
networks in the cabinet
When multiple port networks exist within a cabinet, Carriers A, B, and C are
listed first and separated from Carriers D and E by a slash (e.g., up/up).
up
Both the Expansion Archangel Link (EAL) and the Indirect
Neighbor Link (INL, if applicable) are available.
Both EAL and INL (if applicable) are not available.
dn
ne
(Near End) The EAL is available but the INL is not available.
( Far End) The INL is available but the EAL is not available.
fe
The following are available for S8700
Multi-Connect cabinets only:
up/up
When two port networks share a cabinet, the first up is
associated with the PN contained in A, B, and C carriers, and the 2nd
up in D and E.
up/up/up
When three port networks share a cabinet, the first is in
carrier A, the second in B and C, and the third in D and E.
up/up/up/up
When four port networks share a cabinet, the first is in
carrier A, the second in B, the third in C, and the fourth in D and E.
up/up/up/up/up When five (the maximum allowed) port networks share
a cabinet, the first is in A, the 2nd in B, the 3rd in C, the 4th in D, and
the 5th in E.
Use list cabinet to display the carriers and port networks in each
cabinet in the system.
Current system time
Issue 1 May 2002