Maintenance Commands
The duration specified in minutes for how long the test call should run. Valid
Duration
durations are 1-120 (minutes) or blank (to indicate the default amount of
Specified
minutes was used to run the test).
The duration specified in minutes for how long the test call has been running.
Duration of
A blank indicates that the default amount of time was used to run the test.
Test
The reason of termination indicates why the test call has terminated. Valid
Reason of
reasons of termination are "finished," "canceled," "overflow," "no bits,"
Termination
"transmission," "internal fail," "data corrupt," and "in progress." A termination
reason of "finished" means the test finished in the specified time. A
termination reason of "canceled" means the test call has been canceled with
the "clear isdn-testcall" command. A reason of "overflow" denotes that the
bits transmitted have overflowed buffer allocation. A reason of "no bits"
means that no bits have been received because the ISDN-PRI test call circuit
connection is bad. A reason of "transmission" means there has been a data
transmission interruption, probably caused from a power hit. A termination
reason of "internal fail" specifies that there is an internal error on the
Maintenance/Test circuit pack. A reason of "in progress" means the test is
still running and a reason of "data corrupt" is used for any other error
condition.
7-356
Issue 1 May 2002
555-233-143