Avaya S8700 Maintenance Manual page 627

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

status pnc
Most fields on this screen display blanks when the PNC is not duplicated.
Whether or not the system has a duplicated PNC (critical-reliability option).
Duplicated?
On a system with duplicated PNC, whether the PNCs are locked by means of the
Software
set pnc lock or reset pnc override-and-lock commands. When this field
Locked?
displays "yes", spontaneous or demand PNC interchanges are not possible. To
enable interchanges, use the set pnc unlock command.
On a system with duplicated PNC, whether or not the standby PNC is busied out
Standby
with the busy pnc command. Interchanges are prevented when the standby is
Busied?
busied out.
Whether the system uses direct-connect connectivity or a center stage switch.
Direct
Connect?
On a duplicated system, this field indicates whether the standby PNC has
Standby
completed a global refresh of duplicated call setup after being released from a
Refreshed?
busyout, or after a system reset.
This field displays "yes" when the anti-thrashing mechanism is in effect,
Interchange
preventing PNC interchanges. This is the case for 5 minutes after a spontaneous
Disabled?
PNC interchange, and for 30 seconds after a demand interchange. The reset
pnc interchange override-and-lock command overrides antithrashing. This
field does not indicate whether a PNC interchange is currently prevented by a
software lock, by insufficient state of health of the standby, or by busyout of the
standby.
555-233-143
NOTE:
This field does not indicate if a partial unrefresh has taken place in
response to a problem on the standby. Only a "functional" state of health
on the standby (all zeros in the state-of-health vector) guarantees that the
standby's call setup matches completely that of the active.
Issue 1 May 2002
7-371