Sign In
Upload
Manuals
Brands
Lucent Technologies Manuals
Touch terminals
SLC 5 Series
Lucent Technologies SLC 5 Series Manuals
Manuals and User Guides for Lucent Technologies SLC 5 Series. We have
1
Lucent Technologies SLC 5 Series manual available for free PDF download: Manual
Lucent Technologies SLC 5 Series Manual (508 pages)
Carrier System
Brand:
Lucent Technologies
| Category:
Touch terminals
| Size: 3.11 MB
Table of Contents
Power up Cabinet or Frame Power Plant Task Index List
56
Table of Contents
56
Acceptance
57
Turn up J1C182BA Power Shelf and Supporting Equipment in Frame, 51, 80, or 90-Type Cabinet RT
58
Turn up J1C182BB Bulk Power Shelf and Supporting Equipment in
65
RT Frame
65
Turn up J1C182BD Power Shelf in 80A Cabinet
68
Turn up ED-7C704-30 Bulk Power Plant in 80D or 80E Cabinet
71
Turn up J1C182PB-1 Optics Power Shelf
75
Install and Test Power Converter Unit (Pcu) in Facility Shelf
132
Does FAIL Indicator on PCU Go off and Remain off
214
If YES, then Proceed to Step 8
214
If NO, then Continue with Step 6
214
Replace PCU
214
Note
214
Replace PCU with PCU Removed Previously
214
Rt Channel Bank Turn up Task Index List
247
Acceptance
250
Procedures, the Quick Reference Cards (Appendix B for Option Settings and Appendix
250
Feature Package Except FP 303
251
Turn up Series 5 RT Blue or White System Equipped for Feature Package 303
264
Add Ds1S to an In-Service Feature Package 303 RT
270
Clear FAIL LED Problems on a Unit During Turnup and Conversion
272
Verify that Correct Complement of Circuit Packs Is Available
275
Use SD-7C117-01 or SD-7C117-02 to Check Bank Wiring. Repeat Procedure from Step 3 after Locating and Correcting Trouble
282
Condition DMM to Measure Volts DC
282
On PCU, Connect DMM Test Leads to GND Jack and −48 Jack
282
Rt Channel Bank Conversions Task Index List
399
Acceptance
400
Convert Series 5 RT from Feature Package a Capability to Feature Package C Capability
401
Convert Feature Package a or C RT to Feature Package C-Autocut
403
Convert Series 5 RT from Feature Package B Mode 2 to
406
Convert Series 5 RT from Feature Package B Mode 1 to
408
Add Special Service Capability to Feature Package B RT
410
Add or Remove Protection Line Option
411
Convert Series 5 RT to any Feature Package Capability
413
Generic Procedures
413
Convert Feature Package B Mode 1 or Mode 2 to
416
Reinstate Feature Package B Following a Failed Conversion to
422
Verify that Correct Complement of Circuit Packs Is Available
428
Advertisement
Advertisement
Related Products
Lucent Technologies SLC-2000 Access System Central Office Terminal
Lucent Technologies Mitel SX200D Series
Lucent Technologies FrameSaver SLV 9126
Lucent Technologies FrameSaver SLV 9128
Lucent Technologies SLC ConnectReach
Lucent Technologies Stinger FS+
Lucent Technologies SI-L16.1C1/1
Lucent Technologies Stinger STGR-LIM-72
Lucent Technologies Stinger STGRRT-LIM-SL-48
Lucent Technologies Stinger Compact Remote
Lucent Technologies Categories
Telephone
Switch
Conference System
Software
Telephone System
More Lucent Technologies Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL