status bri-port
Table 7-45. Interpreting BRI-Port Status Reports — Continued
Error
Aux
Type
Data
Associated Test
BRI
0-126
L3-Assigned
555-233-143
Alarm
On/Off
Level
Board
Test to Clear Value
ext#
blank
This is a transitory state for BRI
endpoints that support MIM
initialization.
1. Wait 5 seconds and repeat the
2. Make sure SPID administration
3. Try replacing the endpoint.
command. If the state has not
changed, continue with Step 2.
on the switch and endpoint are
consistent. Repeat status
bri-port to determine whether
the Layer 2 state of the
signaling link is
. If it is
L3-Established
not, go to Step 3.
Repeat status bri-port to
determine whether the Layer 2
state of the signaling link is
L3-Established
. If it is
not, follow normal escalation
procedures.
Continued on next page