status bri-port
Table 7-45. Interpreting BRI-Port Status Reports — Continued
Error
Aux
Type
Data
Associated Test
ASAI
0-63
Established
BRI
0-126
Established
BRI,
64-126
Established
ASAI
BRI
64-126
L3-Established
555-233-143
Alarm
On/Off
Level
Board
Test to Clear Value
blank
blank
This is a transitory state for ASAI
adjuncts. ASAI signaling is
connected at Layer 2 but the Layer 3
Restart procedure has not been
completed between switch and
adjunct.
1. Check the adjunct by following
2. Repeat status bri-port and
ext#
blank
This is the normal state for non-MIM
initializing, fixed, and automatic TEI
BRI endpoints.
blank
blank
This is a transitory state for
automatic TEI BRI endpoints that
support MIM initialization.
1. Verify that SPID administration
2. Try replacing the endpoint.
ext#
blank
This is the normal state for
automatic TEI BRI endpoints that
support MIM initialization.
the recommended repair
procedures of the manufacturer.
determine whether the L2 state
of the signaling link is
L3-Established. If it is not,
follow normal escalation
procedures.
on the switch and the endpoint
are consistent. Repeat status
bri-port to determine whether
the Layer 2 state of the
signaling link is
L3-Established
.
Repeat status bri-port to
determine whether the Layer 2
state of the signaling link is
L3-Established
. If it is
not, follow normal escalation
procedures.
Continued on next page