Avaya S8700 Maintenance Manual page 556

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Commands
Table 7-45. Interpreting BRI-Port Status Reports — Continued
Error
Aux
Type
Data
Associated Test
BRI
0-126
L3-Assigned
7-300
Issue 1 May 2002
Alarm
On/Off
Level
Board
Test to Clear Value
ext#
yes
This is a transitory state for BRI
endpoints that support MIM
initialization when a SPID Facility
test has been used to initialize the
station.
1. Wait 5 seconds and repeat the
2. Make sure SPID administration
3. Try replacing the endpoint.
command. If the state has not
changed continue with Step 2.
on the switch and endpoints are
consistent. Repeat status
bri-port to determine whether
the Layer 2 state of the
signaling link is
L3-Established
. If it is
not, go to Step 3.
Repeat status bri-port to
determine whether the Layer 2
state of the signaling link is
. If it is
L3-Established
not, follow normal escalation
procedures.
Continued on next page
555-233-143