set options
DS1 Central Office Trunks (CO-DS1)
DS1 Direct Inward Dialing Trunks (DID-DS1)
DS1 Tie Trunks (TIE-DS1)
ISDN Trunks (ISDN-TRK)
Tie Trunks (TIE-TRK)
Circuit Pack MOs affected by this Command
NOTE:
Although alarms on these MOs may appear as warnings, the alarms should
be investigated with user-reported problems.
NOTE:
Trunks that are not members of Trunk Groups, (for example, PCOLs) are
downgraded according to the alarm severity of group one.
DS1 Interface Circuit Pack (DS1-BD)
Adjunct-Related MOs affected by this Command
NOTE:
Although alarms on these MOs may appear as warnings, the alarms should
be investigated with user-reported problems.
ASAI adjunct (ASAI-ADJ)
Avaya adjunct port (ATT-PORT)
Ethernet ASAI port (LGATE-PT)
Ethernet ASAI adjunct (LGATE-AJ)
Ethernet Avaya port (ATTE-PT)
Ethernet Avaya adjunct (ATTE-AJ)
ISDN-BRI ports connected to adjuncts (ABRI-PORT)
Although adjuncts are administered as stations, the administration of alarm
severity for the station alarm group does not affect the alarm severity levels of the
adjuncts. Similarly, the administration of alarm severity for the adjunct alarm
group does not affect the alarm severity levels for other types of stations.