Set Options - Avaya S8700 Maintenance Manual

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Commands

set options

This command allows the user to administer whether certain alarms are reported
to INADS or whether they are downgraded to a minor alarm, warning alarm, or no
alarm.
Synopsis
set options
Permissions
The following default logins may execute this command: inads, init .
Examples
set options
Description
This special command enables the technician (that is, remote user with INADS
permission) to select which types of maintenance categories report alarms
automatically and which types require the customer to call in. Judicious use of
this command can reduce the number of ineffective alarms to the TSC. For the
set options command to be effective, the default settings specified in this section
should always be used. These settings are not intended to be changed on a
per-system basis. Special circumstances (for example, special studies) may
require temporary changes under the guidance of Tiers 3 and 4.
NOTE:
Alarms cannot be upgraded.
Defaults
Initially, the alarm reporting options for On-board Trunk Alarms (Alarm Group 1),
both major and minor, are set to "yes" (y); all others are set to "warning" (w).
Every trunk group is associated with alarm severity group 1 by default.
Parameters
None.