Maintenance Commands
Associated Link MOs affected
by this Command
NOTE:
Although alarms on these MOs may appear as warnings, the alarms should
be investigated with user-related problems.
PN's Maintenance circuit pack (MAINT)
Expansion Interface (EXP-INTF)
ISDN-PRI signaling group (ISDN-SGR)
Journal printer (JNL-PRNT)
PMS link (PMS-LINK)
Primary CDR link (PRI-CDR)
Synchronization (SYNC)
System printer (SYS-PRNT)
TDM clock (TDM-CLK)
Tone Generator circuit or circuit pack (TONE-BD)
Field Help
Since every field on the first page may have the same values, pressing
any field of this page presents the following help message:
m(inor) n(o) r(eport) w(arning) y(es)
The following is a description of the values:
Downgrade the major alarm to a minor alarm and report the alarm to INADS.
m(inor)
Do not log the alarm or report it to INADS.
n(o)
Downgrade the alarm to a warning and report the warning to INADS.
r(eport)
Downgrade the alarm to a warning, log it but do not report the alarm to INADS.
w(arning)
Log and report the alarm to INADS.
y(es)
Every field on page 2 may have the same values. Pressing HELP in any field of
page 2 gives the following field help message:
Enter alarm group number:
The alarm group number is a way of distinguishing four different groups of alarms.
These alarm groups allow the user to specify that alarms in different groups are