IPMEDPRO (IP Media Processor Circuit Pack)
Table 301. TEST #53 SAKI Sanity Test — Continued
Error
Test
Code
Result
PASS
The circuit pack initializes correctly.
Any
NO
This is normal if the test is being done when (a) the board is not
BOARD
physically in the system or (b) the system is booting up. Otherwise,
there is some inconsistency between the physical configuration and
the data kept in the system.
555-233-119
Description/ Recommendation
1. Run the short test sequence.
1. Verify that the board is physically in the system.
2. Verify that the system is not in a stage of booting up.
3. Retry the command at 1-minute intervals for a maximum of 5
times.