Avaya DEFINITY Server CSI Maintenance Manual page 1100

Table of Contents

Advertisement

Table 229. TEST #140 Red Alarm Inquiry Test — Continued
Error
Test
Code
Result
0
NO
The test could not relate the internal ID to the port (no board).
BOARD
This could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
This should re-establish the linkage between the internal ID and the port.
1100
Issue 5 October 2002
Description/ Recommendation
1. Check to ensure that the board translations are correct. Use the add ds1
UUCSS command to administer the DS1 interface if it is not already
administered.
2. If board was already administered correctly, check the error log to
determine if the board is hyperactive. If this is the case, the board is shut
down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, issue the
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
Continued on next page
555-233-119

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents