Mtp Reset Test - Avaya DEFINITY Server CSI Maintenance Manual

Table of Contents

Advertisement

Maintenance Objects

MTP Reset Test (#101)

This test is destructive. The test resets the Maintenance/Tape Processor. The
destructive nature of this test causes the following:
Administration terminal to log off
CDR port to terminate data transmission
Any current tape access to terminate and also to tear down any remote
access INADS connection
Table 410. TEST #101 MTP Reset Test
Error
Test
Code
Result
1029
ABORT
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
10102
ABORT
10104
ABORT
10105
FAIL
10106
FAIL
PASS
1512
Issue 5 October 2002
Description/ Recommendation
Refer to STBY-SPE Maintenance documentation for a description of these
error codes.
System software resources required for this test are not available.
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
The MTP did not respond to being reset.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, replace the Processor circuit pack.
The Maintenance/Tape Processor was reset, but it responded with a NOT
PASS status, indicating that it did not pass initialization correctly. The MTP
is not functioning correctly. The system should continue to function, but it
will not have the ability to save translation to tape, or to read tape if the
system needs to be rebooted. Environmental monitoring is lost, as is
communication with the Standby Processor.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If test continues to fail, replace the Processor circuit pack.
The Maintenance/Tape Processor was reset, and it passed initialization
correctly. The other MTP tests should be examined to verify that the MTP is
functioning correctly.
1. Enter test processor a/b and verify that the MTP is functioning
correctly.
Continued on next page