Avaya DEFINITY Server CSI Maintenance Manual page 1686

Table of Contents

Advertisement

Maintenance Objects
Table 497. TEST #7 Conference Circuit Test — Continued
Error
Test
Code
Result
1003
ABORT
1004
ABORT
1018
ABORT
1020
ABORT
2000
ABORT
2100
ABORT
2053
ABORT
1686
Issue 5 October 2002
Description/ Recommendation
The system could not allocate a tone receiver for the test. The system may
be oversized for the number of tone detectors present or some of the tone
detectors may be out of service. Issue the list measurements
tone-receiver command to display basic information about the system's
tone receivers.
1. Look for TTR-LEV errors in the error log. If present, refer to the
TTR-LEV Maintenance documentation.
2. Look for TONE-PT errors in the error log. If present, refer to the
TONE-PT Maintenance documentation.
3. If neither condition exists, retry the test at 1-minute intervals for a
maximum of 5 times.
The port was seized by a user for a valid call. Use the display port
PCSSpp command to determine the trunk group/member number of the
port. Use the status trunk command to determine the service state of the
port. If the service state indicates that the port is in use, then the port is
unavailable for certain tests. You must wait until the port is idle before
retesting.
1. If the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times.
Test disabled via administration. This only applies to analog stations.
1. To enable test, set the Test field on the station administration screen for
the particular analog station being tested to "y." Use the change
station <extension> command.
The test did not run due to a previously existing error on the specific port or
because of a more general circuit pack error.
1. Examine the Error Log for existing errors against this port or circuit
pack, and attempt to diagnose the previously existing error.
Response to the test request was not received within the allowable time
period.
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
At least one of the following errors is found on the DS1 circuit pack: 1281—
Loss of signal, 1793—Blue Alarm, 2049—Red Alarm, 2305—Yellow Alarm,
1537—Hyperactivity.
Look for the above error types in the Hardware Error Log and follow the
procedures given in the appropriate DS1-BD or UDS1-BD maintenance
documentation for the listed error types.
Continued on next page