PPP-PT (Control LAN Packet/Port)
Error Log Entries and Test to Clear Value
Table 402. PPP-PT Error Log Entries
Aux
Error Type
Data
1
0
0
1 (a)
0
257 (b)
0
513 (c)
0
769 (d)
0
1281 (e)
0
1537, 1538
See
(f)
note
1793-1920
See
(g)
note
2305-2560
See
(h)
note
2561-2816
See
(h)
note
3329 (i)
35768
3585 (j)
0-1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Notes:
a. Error Type 001: SCOTCH Synchronous Looparound Test (#1275) failed.
1. Test the port (test port UUCSSpp long).
2. Refer to SCOTCH Synchronous Looparound Test (#1275) repair
555-233-119
Associated Test
Any
SCOTCH Sync
Looparound
Test (#1275)
Session Status Test
(#1286)
TCP/IP Ping Test
(#1281)
TDM Looparound
Test (#1285)
procedures.
Alarm
On/Off
Level
Board
Any
Any
MINOR
ON
WARNING
OFF
MINOR
OFF
WARNING
OFF
MINOR
OFF
WARNING
OFF
MAJOR
ON
Issue 5 October 2002
Test to Clear Value
test port UUCSSpp s
test port UUCSSpp l r 3
test port UUCSSpp l r 3
Continued on next page
1497
Need help?
Do you have a question about the DEFINITY Server CSI and is the answer not in the manual?
Questions and answers