Avaya DEFINITY Server CSI Maintenance Manual page 1174

Table of Contents

Advertisement

Table 259. TEST #1282 Link Integrity Inquiry Test — Continued
Error
Test
Code
Result
2500
ABORT
FAIL
PASS
1174
Issue 5 October 2002
Description/ Recommendation
Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
Link integrity lost due to problem with attachment of Ethernet cable to the
port.
1. Repeat the test.
2. If the test fails, verify that the cable properly is secured to Ethernet port
and to the bus.
3. Verify the CLAN circuit pack link integrity LED is glowing.
4. Retry the test.
5. If problem persists, refer to Ethernet Local Looparound Test (#1278)
repair procedures.
The Ethernet Link Integrity Test (#1282) detects good connections.
Continued on next page