Avaya DEFINITY Server CSI Maintenance Manual page 899

Table of Contents

Advertisement

CO-DS1 (DS1 CO Trunk)
Hardware Error Log Entries and Test to Clear
Values
Table 154. DS1 CO Trunk Error Log Entries
Error
Aux
Type
Data
1
0
0
1 a)
57408
1(a)
57487
15(b)
Any
18(c)
0
130 d)
257 e)
57392
513(f)
57393
769 g)
57484
1025
1281
1537
1793(h)
2562(i))
16665
2817(j)
52992
3840(k)
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2.
This alarm will only be raised when the System-Parameter Country form has the Base Tone
Generator field set to 4 (Italy). This alarm will be a MINOR alarm unless 75% or more trunks in this
trunk group are out of service, the alarm will be upgraded to a MAJOR alarm.
3.
Minor alarms on this maintenance object (MO) may be downgraded to Warning alarms based on
the values used in the set options command. If the Minor alarm is not downgraded by the set
options values, the Minor alarm is upgraded to a Major alarm if 75 percent of the trunks in this group
are alarmed.
555-233-119
Associated Test
Any
Any
Port Audit and
Update Test (#36)
busyout trunk
WARNING
<grp>/<mbr>
None
WARNING
DS1 CO Dial Tone
MIN/MAJ
Seizure Test (#314)
DS1 CO Dial Tone
MIN/MAJ
Seizure Test (#314)
DS1CO Dial Tone
WARNING
Seizure Test (#314)
Conference Circuit
MAJ/MIN/
Test (#7)
WRN
NPE Crosstalk Test
MAJ/MIN/
(#6)
WRN
Port Audit and
Update Test (#36)
Alarm
On/Off
Level
Board
Any
test trunk <grp>/<mbr>
OFF
release trunk
<grp>/<mbr>
ON
test trunk <grp>/<mbr>
2
OFF
2
OFF
OFF
test trunk <grp>/<mbr>
ON
test trunk <grp>/<mbr> r 4
3
ON
test trunk <grp>/<mbr> r 3
3
ON
test board PCSS l
Issue 5 October 2002
Test to Clear Value
Continued on next page
899