Avaya DEFINITY Server CSI Maintenance Manual page 883

Table of Contents

Advertisement

CLAN-BD (Control LAN Circuit Pack)
System Technician-Demanded Tests: Descriptions
and Error Codes
Investigate errors in the order they appear in the table below.
Order of Investigation
Control Channel Loop-Around Test #52
Circuit Pack Restart Test #252
Invalid LAPD Frame Error Counter Test #597
PPE/LANBIC Receive Parity Error Counter Test #595
Receive FIFO Overflow Error Counter Test #596
Packet Interface Test #598
Congestion Query Test #600
Link Status Test #601
1.
D = Destructive; ND = Nondestructive
Control Channel Loop-Around Test (#52)
This non-destructive test fails if the circuit pack does not return to a sane state
after being reset. This test queries the circuit pack for its code and vintage, and
verifies its records.
Table 142. TEST #52 Control Channel Loop-Around Test
Error
Test
Code
Result
None
ABORT
Could not allocate the necessary system resources to run test.
2100
FAIL
The circuit pack failed to return the code or vintage.
PASS
Test successful.
555-233-119
Description/ Recommendation
1. Retry the command at 1-minute intervals, up to 5 times.
2. If the problem persists, escalate the problem.
1. Retry command at 1-minute intervals, up to 5 times.
2. Reset the board (reset board UUCSS).
3. If reset aborts with error code 1115, busyout (busyout board UUCSS),
reset (reset board UUCSS), and release board (release board
UUCSS).
4. If test continues to fail, replace the circuit pack.
5. Escalate the problem if failures continue.
Short Test
Long Test
Sequence
Sequence
X
X
X
X
X
X
X
X
X
X
X
Issue 5 October 2002
1
D/ND
ND
D
ND
ND
ND
ND
ND
ND
883