Avaya DEFINITY Server CSI Maintenance Manual page 880

Table of Contents

Advertisement

Maintenance Objects
n. Error Type 2817-2819: Congestion Query Test (#600) failed.
The Error Types correspond to the descriptions:
2817
2819
If:
Active buffers exceed threshold,
1. Refer to Congestion Query Test (# 600) for Abort and Fail 3601s.
o. Error Type 3073: Remote Socket Control Link (RSCL) or Link Status Test
(#601) failed. This failure may be due to:
If:
RSCL disconnects at link level
Link cannot be reconnected quickly
p. Error Type 3330: Critical failure in Packet Bus interface.
Below, Error Types correspond to descriptions.
If the switch detects:
1 error,
2 errors in 15 minutes,
1. Attempt to clear the alarm (reset board UUCSS).
2. If alarm persists, replace circuit pack.
880
Issue 5 October 2002
All buffers exhausted.
Utilized buffers exceed threshold.
This circuit pack
The packet bus
The packet interface circuit pack.
Then it:
Resets circuit pack.
Raises MINOR alarm.
Then:
CLAN enters congested state.
Then:
Link fails
Switch raises MINOR alarm
555-233-119

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DEFINITY Server CSI and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents

Save PDF