Maintenance Objects
MTP Auxiliary Loop Around Test (#229)
This test is a nondestructive test. The test places the Auxiliary channel of the MTP
into a loop around mode, and it verifies the data integrity of the channel. The
Auxiliary channel is used as the CDR output port.
Table 416. TEST #229 MTP Auxiliary Loop Around Test
Error
Test
Code
Result
1029
ABORT
Refer to STBY-SPE Maintenance documentation for a description of these
2014
error codes.
2015
2016
2017
2018
2020
2022
2024
2025
2051
1000
ABORT
The system software resources required for this test are not available.
1018
ABORT
The test has been disabled via administration. The change
system-parameters cdr command needs to administer CDR.
2000
ABORT
Response to the test request was not received within the allowable time
period.
2033
ABORT
Internal system error
2034
Port busy
Retry the command at 1-minute intervals a maximum of 5 times.
22902
ABORT
The system software resources required for this test are not available.
22903
FAIL
The Auxiliary channel failed the Loop Back Test. The AUX port is probably not
sending any auxiliary data to the auxiliary collection device.
PASS
The Auxiliary channel passed the Loop Back Test. The auxiliary port is
functioning correctly.
1522
Issue 5 October 2002
Description/ Recommendation
1. Retry the command at 1-minute intervals a maximum of 5 times.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If test continues to fail, replace the Processor circuit pack.
1. If no auxiliary data is being recorded, check the auxiliary collection
device, and verify that it has been set up and connected correctly.