BRI-SET, ASAI-ADJ, BRI-DAT
Hardware Error Log Entries and Test to Clear
Values
Table 119. BRI-SET/ASAI-ADJ Error Log Entries
Error
Aux
Type
Data
1
0
0
Any
2(a)
2-102
None
18
0
busyout station
ext
130 (b)
257(c)
Any
BRI Layer 3
Query (#629)
351(d)
0
None
513(e)
0
None
769(f)
0
None
2561(g)
0
None
2562-
0
None
2566(h)
2567(o)
0
None
2568(p)
0
None
2817(i)
0
XID Test
(#628)
555-233-119
Alarm
Associated
Level
Test
BRI-PORT
Any
WARNING
WARNING
WARNING
WARNING
WARNING
Alarm Level
ABRI-PORT
ATT-PORT
On/
LGATE-PORT
Off
ATTE-PT
Board
Any
Any
MAJOR/
OFF
2
WARNING
ON
MAJOR/
OFF
2
WARNING
WARNING
OFF
MAJOR
OFF
MAJOR/
OFF
2
WARNING
Continued on next page
Issue 5 October 2002
Test to Clear
Value
test BRI-SET or
ASAI-ADJ
ATT-ADJ
LGATE-AJ
ATTE-AJ
release station
<ext>
test port PCSS
sh
test station ext r
2
test
data-module ext
r 2
busyout and
release station
test station ext r
2
test
data-module ext
r 2
821