MIS (Management Information System)

MIS (Management Information
System)
MO Name (in
Alarm
Alarm Log
Level
MIS
WRN
The Management Information System (MIS)/Call Management System (CMS) MO
is used only for administering MIS translations, such as trunks and stations. There
are no hardware failures associated with this MO.
NOTE:
To diagnose MIS link hardware errors and alarms, see PKT-INT (Packet
Interface).
The MIS/CMS is an adjunct processor that collects ACD data sent from the
system. To change MIS translations, a system administrator must first enter a
busyout mis command at the terminal. When the MIS is busied out, the system
stops sending ACD data to the MIS, and a Warning alarm is raised. When
finished, a release mis command should be entered at the terminal. This clears
the Warning alarm and allows the switch to send ACD data to the MIS.
Error Log Entries and Test to Clear Values
Error Type
Aux Data
1
0
0
18(a)
0
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Note:
a. When the busyout MIS command is issued, no data is sent to the
MIS/CMS regardless of the link state. To allow data to be sent to MIS/CMS,
a release mis command must be issued from the terminal.
555-233-119
Initial Command to Run
release mis
Associated Test
Any
busyout mis
Full Name of MO
Management Information System
On/Off
Alarm Level
Board
Any
Any
WARNING
ON
Issue 5 October 2002
Test to Clear Value
release mis
release mis
1395