Maintenance Objects
Table 433. Analog Line Error Log Entries
Error
Aux
Type
Data
15(b)
Any
18
0
257(c)
40973
513(d)
769
2817(e)
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2.
Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the
set options command.
Notes:
a. Error Type: 1 - These are in-line errors and can only be resolved over time.
1546
Issue 5 October 2002
— Continued
Associated
Alarm
Test
Level
Audits and
Updates
Test (#36)
busy-out
WRN
station
extension
none
Station
WRN
Present Test
(#48)
Battery Feed
MIN/
2
Test (#35)
WRN
Hyperactive
MINOR
40960 indicates that too many simultaneous incoming ringing
attempts were made on this board. Only 4 ports on a board may ring
simultaneously. A 5th incoming call will cause an inline error from
the board.
40975 indicates that the terminal equipment was on-hook when
ring-tip was detected during ringing. This usually indicates a failure
in the terminal equipment or the type of terminal has a low ringer
impedance. Call the terminal equipment and verify that the terminal
rings. If the terminal does not ring, then replace it. Otherwise, issue
the test port UUCSSpp command, and follow the procedure for
Test #48.
40977 indicates that terminal equipment was not connected when
ringing was attempted. Run the short test via the test port
UUCSSpp command, and follow the procedure for the results of
Test #48.
On/Off
Board
Test to Clear Value
ON
release station extension
OFF
test port UUCSSpp sh r 2
ON
test port UUCSSpp sh r 2
OFF
Continued on next page