OPS-LINE (DS1 OPS Line)
Hardware Error Log Entries and Test to Clear
Values
Table 373. DS1 OPS Maintenance Error Log Entries
Error
Aux
Type
Data
1
0
0
Any
15(a)
Any
Audit and Update
Test (#36)
18(b)
0
busyout station <ext>
130(c)
None
1281
Conference Circuit
Test (#7)
1537
NPE Crosstalk Test
(#6)
1793(d)
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Notes:
a. This is a software audit error that does not indicate any hardware
malfunction. Run the Short Test Sequence and investigate associated
errors (if any).
b. The DS1OPS Line has been busied out by a busyout station <ext>
command. No calls can be made on this line.
c. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
d. Error Type 1793 indicates a problem with the DS1 Interface circuit pack.
Since there is no error against the OPS-LINE port, no alarm is raised
against the OPS-LINE port. However, there should be errors logged
against the DS1 Interface circuit pack. Look for DS1-BD errors in the
Hardware Error Log and follow procedures provided in the DS1-BD (DS1
Interface Circuit Pack) Maintenance documentation.
555-233-119
Associated Test
Alarm Level
Any
WARNING
WARNING
MINOR
MINOR
On/Off
Board
Test to Clear Value
Any
test station <ext> sh r 1
OFF
release station <ext>
ON
test station <ext>
ON
test station <ext> l
ON
test station <ext> l
test circuit pack PCSS l
Issue 5 October 2002
1423
Need help?
Do you have a question about the DEFINITY Server CSI and is the answer not in the manual?
Questions and answers