Avaya DEFINITY Server CSI Maintenance Manual page 928

Table of Contents

Advertisement

Maintenance Objects
Table 162. TEST #3 CO Demand Diagnostic Test — Continued
Error
Test
Code
Result
0
NO
BOARD
928
Issue 5 October 2002
Description/ Recommendation
The test could not relate the internal ID to the port (no board).
1. Check to ensure that the board translations are correct. Translate the
board, if necessary.
2. Issue busyout board.
3. Issue reset board.
4. Issue release busy board.
5. Issue test board. This should re-establish the linkage between the
internal ID and the port.
Continued on next page
555-233-119

Hide quick links:

Advertisement

Table of Contents
loading