Avaya DEFINITY Server CSI Maintenance Manual page 1458

Table of Contents

Advertisement

Maintenance Objects
d. The Maintenance/Test Packet Bus port has detected open leads on the
Packet Bus. The Aux Data value indicates the number of open leads.
e. Packet circuit pack, port, and endpoint maintenance has been disabled due
to a Packet Bus failure. The Aux Data value indicates which sources have
reported errors that have caused maintenance to be disabled. These
sources include the following:
The Aux Data values that indicate these sources are identified in the
following table:
Aux Data
1
2
3
4
5
6
7
f. Packet circuit pack, port, and endpoint maintenance has been disabled due
to more than one circuit pack reporting in-line errors. If this occurs more
than three times in 15 minutes (that is, if maintenance is disabled due to
errors and then re-enabled because no more errors are reported), a Minor
alarm is raised against the Packet Bus. Note that this error may still be
present in the error log even if the "Circuit Pack Audit Test" reports that only
one circuit pack has indicated a problem. This occurs if more than one
circuit pack reported errors with in any one minute interval since the Packet
Bus fault occurred.
1458
Issue 5 October 2002
In-line errors from Packet circuit packs.
Packet Bus fault report from the Maintenance/Test Packet Bus port.
Packet Circuit
Pack
X
X
X
X
NOTE:
It is important to remember that problems reported by Packet circuit
packs may be caused by any circuit pack. However, only Packet
circuit packs can detect such problems (inasmuch as TDM-only
circuit packs are not affected by these problems).
Maint/Test
Circuit Pack
X
X
X
X